AutoPrep1000 Pilot-scale Preparative Liquid Chromatography System

The Unique AutoPrep series fully automatic preparative liquid chromatography system enables the separation and purification of pharmaceuticals including small molecules, natural products, peptides and oligonucleotides.
  • Product Introduction
  • Product Parameters
  • Related Documents

    The Unique AutoPrep series fully automated preparative liquid chromatography system is designed for the separation and purification of pharmaceuticals such as small molecules, natural products, peptides, and oligonucleotides. The Unique AutoPrep1000 system is suitable for pilotscale production and purification. The system comprises an autosampler, a preparative chromatography main unit, and preparative columns, enabling the fully automated execution of sample injection, separation and purification, and target fraction collection in a stream-lined workflow.

     

    Product Features System Configuration Overview 

    Multiple Configuration Options

    ● Binary high-pressure gradient or isocratic pumps are available.

    ● Multi-wavelength UV detectors. A variety of detectors are optional, including Conductivity, pH, and

    High Level of Automation

    ● Capable of automated program execution, including automatic sample loading, separation & purification, and target fraction collection.

    ● Automated result integration, data acquisition, saving, and management.

  • Item  Specifications
    Maximum Pressure Resistance  10MPa
    Flow Rate Range  5ml/min-1000ml/min
    FlowAccuracy  ±1%@5-1000ml/min
    Flow Repeatability  RSD≤0.5%
    Wavelength  280nm/260nm/254nm:Select one fixed wavelength (L1)
     200-600nm:Select two fixed wavelengths (L2)
     200-400nm:Select anytwo wavelengths(M402)
     200-600nm:Select any four wavelengths(M604)
     200-800nm:Select anyfour wavelengths(M804)
     190-800nm:Select any four wavelengths(M894)
    Noise  ±4*10⁵AU(@254nm ,1S)(L2/M402/M604/M804)
     ±2×105AU(L1)
    Drift  1×10³ AU/HR(L2/M402/M604/M804)
     5×104AU/HR(L1)
    Wavelength Indication Error  ± 1nm
    Wavelength Repeatability  ±1nm(L2/M402/M604/M804)
     ±0.1nm(L1)
    pH  ±0.1( 2-12)
    Temperature Accuracy  ±0.5℃(within the range of 4-50℃)
    Conductivity  ±0.02 mS/cm or2%(within the range of 0.1-300 mS/cm)
    Inlet Quantity  4+4(8 optional)
    Outlet Quantity  4(8 optional)
    Column Compatibility  70-200mm