CN.
AutoPure
AutoPure
+
  • AutoPure
  • AutoPure

AutoPure Protein Purification System

A richly configured laboratory-grade chromatography system for rapid process development and small-scale sample preparation.
  • Product Introduction
  • Product Parameters
  • Related Documents

    Unique AutoPure selects core components from well-known manufacturers in Europe and America, ensuring stable performance and high precision. All parts in contact with the sample are made of biocompatible materials, providing excellent biocompatibility.

    Paired with the Unique CDSystem chromatography workstation, it offers powerful functionality, advanced performance, and high automation.

     

    Product Features:

    ● High-precision pump configuration

    ● Multiple column positions available

    ● High degree of automation

    ● Methods can be flexibly edited

    ● Compatible with different types of collectors.

     

  • Configuration

    Product Name

    Technical Parameter

    Standard configuration

    Unique AutoPure
    infusion pump

    Unique AutoPure25

    Unique AutoPure100

    Unique AutoPure150

    Unique AutoPure300

    Dual Pump System

    Flow rate range:

    0.001- 25ml/min

    Withstand voltage range:

    0-27.5MPa(4000psi)

    Flow accuracy:±1.2%

     

    Dual Pump System

    Flow rate range:

    0.001-100ml/min

    Withstand voltage range:

    0-10MPa(1500psi)

    Flow accuracy:±1.2%

    Dual Pump System

     Flow rate range:

    0.001- 150ml/min

    Withstand voltage range:

    0- 5MPa(725psi)

     Flow accuracy:±1.2%

    Dual Pump System

    Flow rate range:

    0.01- 300ml/min

    Withstand voltage range:

    3.5MPa(500psi)

    Flow accuracy:±2%

    Flow rate reproducibility: RSD ≤ 0.5%
    Gradient type: linear, isocratic, step gradient.

    Automatic sample injection valve

    Three-position seven-port valve, software-controlled for reverse control, supports quantitative sampling; supports Load, Inject, and Waste functions.

    Fixed single-wavelength detector

    LED light source, fixed single wavelength, lifespan ≥ 8000 hours.

    Temperature sensor

    Reading Range: 0-100°C,  capable of temperature compensation for conductivity and pH.

    Conductivity detector

    Display Range: 0.001-999.99 mS/cm

    includes temperature compensation.

    Back pressure valve

    20psi(2ml/min)

    Online filter

    20 μm Titanium Alloy Filter

    Dynamic mixer

    Mixing Chamber Options: 0.6 ml, 2 ml, or 5 ml

    Chromatography column clamp

    2 pcs

    Startup package

    Startup Package: Includes tubing, fittings, maintenance tools, manual, and dongle

    Control system

    Control System: Includes branded computer, keyboard, mouse, and bilingual software; capable of 24-hour continuous operation

     

    Optional configuration

    Product Name

    Technical Parameter

    pH detector

    pH Range: 0-14; Detection Range: 2-12; Accuracy: ±0.1; includes temperature compensation

    Bubble sensor

    Used for monitoring sample loading and detecting bubble formation in the system

    Buffer inlet valve

    A/B Pumps: Optional inlet valves with 2, 6 (for 300 systems only), 8, or 10 channels

    UV detector

    L2 Fixed Dual Wavelength: Detection range at 280 nm and 260 nm

    DAD402 Variable Dual Wavelength: Detection range from 200 - 400 nm, full spectrum direct reading, can detect two arbitrary wavelengths simultaneously

    DAD604 Variable Quadruple Wavelength: Detection range from 200 - 600 nm, full spectrum direct reading, can detect four arbitrary wavelengths simultaneously

    DAD804 Full Wavelength Detection: Detection range from 200 - 800 nm, full spectrum direct reading, can detect four arbitrary wavelengths simultaneously

    DAD894 Full Wavelength Detection: Detection range from 190 - 800 nm, full spectrum direct reading, can detect four arbitrary wavelengths simultaneously

    Outlet valve

    Optional large-volume collection valves with 2, 8, or 10 channels.

    Fraction collector

    Frac-01: Supports sample collection from 96-well plates up to a maximum of 300 ml; comes standard with one collection rack (compatible with 96-well plates or various sizes of centrifuge tubes and test tubes)

    Frac-02: Supports sample collection from 96-well plates up to a maximum of 300 ml; comes standard with two collection racks (compatible with 96-well plates or various sizes of centrifuge tubes and test tubes)

    Frac-02P: Supports sample collection from 96-well plates up to a maximum of 300 ml; comes standard with two collection racks (compatible with 96-well plates or various sizes of centrifuge tubes and test tubes)

    Frac-02C: Supports sample collection from 96-well plates up to a maximum of 300 ml; comes standard with two collection racks (compatible with 96-well plates or various sizes of centrifuge tubes and test tubes)

    Column position

    valve

    Single Column Position Valve: Supports forward/reverse/bypass

    Three Column Position Valve: Can connect three chromatography columns and bypass simultaneously; each column position supports forward and reverse flushing

    Six Column Position Valve: Can connect six chromatography columns and bypass simultaneously; each column position supports forward and reverse flushing

    Pressure monitoring

    Pre-column Pressure Monitoring

    Pre-column and Post-column Pressure Monitoring

    Sample pump

    SP25: Flow rate range 0.001 - 25 ml/min, pressure range 0 - 27.5 MPa, flow rate accuracy ±1.2%

    SP100: Flow rate range 0.01 - 100 ml/min, pressure range 0 - 10 MPa, flow rate accuracy ±1.2%

    SP150: Flow rate range 0.01 - 150 ml/min, pressure range 0 - 5 MPa, flow rate accuracy ±1.2%

    SP300: Flow rate range 0.1 - 300 ml/min, pressure range 0 - 3.5 MPa, flow rate accuracy ±2%

    Sample inlet valve

    Optional 2 , 6 , 8 , 1 0 ports inlet valve

     

  • Protein Purification System-AutoPure

Contact Us

Products of Interest (Multiple Selection)
Services Needed (Multiple Selection)
Submit
%{tishi_zhanwei}%

Inscinstech Co., Ltd.

Provide integrated solutions for biopharmaceutical CMC from upstream and downstream processes to laboratory analysis.

Contact Us