AutoTFF075 Crossflow System

Fully automatic lab scale tangential flow filtration system, with automatic TMP optimization and dialysis point optimization functions, best tool for process development, process characterization, filter lifetime testing, etc.
  • Product Introduction
  • Product Parameters
  • Related Documents

    Unique AutoTFF075 is a flexible and automated lab scale crossflow filtration system that can be used with hollow fibers or cassette filters for concentration, diafiltration or clarification of samples. It is widely used in biological product process, such as antibodies, recombinant proteins, mRNA, nucleic acids, viral vectors, etc. Its flexible configuration allows for manual operation and highly automated process control. Combined with a powerful intuitive management system, it is suitable for TFF process development, scale up study, and sample preparation

     

    Features

    ● Automatic TMP control, weighing, feeding, precise control of concentration ratio and diafiltration volume.

    ● Compact design, small recirculation volume, to meet high concentration requirements.

    ● The User friendly control software offers easily recipe setup, operation control, data recording and user management.

    ● Optional permeate pump for comprehensive microfiltration process control.

    ● High automation with pre-defined method modules, recipe and recipe sequence.

    ● Optional conductivity sensor, pH, UV, for comprehensive process monitoring.

    ● Adapt to different type of cassette filters and hollow fibers.

     

    Three models available for flexible selection.

     

    Unique AutoTFF075-L: Peristaltic Pump Basic Version

    Unique AutoTFF075-M: Peristaltic Pump version with multiple options

    Unique AutoTFF075-MD: Diaphragm Pump version with multiple options

  • General Parameters

    Dimensions(LxDxH,mm)

    580 x 355 x 640 (filter holder not included)

    Power Supply

    240VAC, 50-60Hz

    Weight

    48kg(include 0.1m² filter holder)

    Power

    160W

    System Language

    Chinese, English

    Ambient Temperature

    2-35°C

     

    System Parameters

    Filtration area

    50cm²- 0.1m²(The specific filtration area can be varied with different filters)

    Maximum feed pressure

    5bar

    Minimum recirculating volume

    20ml (when using standard tubing)

    Process temperature

    2-50°C

    Feed pump flow rate

    0-700ml/min ((Max flowrate 1200ml/min with 25#tubing))

    Transfer pump flow rate

    0-600ml/min

    Permeate pump flow rate

    0-300ml/min

    Recirculation vessel volume

    A 1000ml circulating vessel comes standard, with 50ml, 250ml, and 500ml vessel available as options

    Stirring speed

    0-300rpm

    Pressure sensor

    Detection range: 0-5 Bar

    Conductivity sensor

    Detection range:0.001-999.99ms/cm

    Temperature sensor

    Integrated in conductivity sensor, detection range: 0-99 ° C

    pH

    Detection range: 0-14

    Retentate and filtration weighing

    0-6kg

    Filter holder

    1 ABS multifunctional holder for 50cm ² Capsule capsule or hollow fiber filters with a diameter no more than 50mm

    1 0.1m ² Stainless steel holder;  Designed to hold 1 to 5 standard filter

    Tube&Connector

    Luer Lock

  • Crossflow System-AutoTFF075.pdf   

Contact Us

Products of Interest (Multiple Selection)
Services Needed (Multiple Selection)
Submit
%{tishi_zhanwei}%

Inscinstech Co., Ltd.

Provide integrated solutions for biopharmaceutical CMC from upstream and downstream processes to laboratory analysis.

Contact Us