CN.
Hicient L-2000 Bio
Hicient L-2000 Bio
+
  • Hicient L-2000 Bio
  • Hicient L-2000 Bio

Hicient L-2000 Bio High-Performance Liquid Chromatograph

With leading independent research and development and innovative technology, it ensures optimized analytical efficiency and testing performance.

Belonging Category: 

  • Product Introduction
  • Product Parameters
  • Related Documents

    The Hicient L-2000 Bio High-Performance Liquid Chromatograph from Yingsais has leading independent research and development and innovative technologies, ensuring optimized analytical efficiency and detection performance. The system is specially designed to meet stringent standards for method reproducibility, linearity, and accuracy, whether for small biomolecules, large molecules, or polymers. Whether high sensitivity or analytical-grade purification is required, the Hicient L-2000 Bio High-Performance Liquid Chromatograph can easily and flexibly complete various tasks under multiple conditions.

     

    Features:

    ● Bio-inert pump  (titanium alloy pump head), with a maximum pressure tolerance of 10500 psi, allowing the use of smaller particle size chromatography packing for higher separation efficiency.

    ● Bio-inert Sample Flow Path: Maintains the integrity of large molecules and prevents adsorption of protein drugs.

    ● Flexible sample tray selection and optional sample chamber cooling function.

    ●  Integrated solvent degasser and seal wash, maximizing normal operating time.

  • Part name

    Technical Parameters

    Bio-inert Pump

    Quaternary Gradient Pump

    Titanium Alloy Material

    Integrated Online Degassing

    Maximum Pressure Tolerance: 10500 psi

    Flow Rate Range: 0.001 – 10 mL/min

    Flow accuracy: ≤± 0.5%

    Flow precision: ≤ 0.06% JJG

    Gradient accuracy: ≤± 0.5%

    Automatic Sample Injector

    Inhalation Type (Full Loop Injection / Partial Injection / Microliter Carry Injection)

    Standard Volume: 100 μL, with optional 20 μL / 50 μL

    Maximum Injection Volume:

    Full Loop Injection = Quantitative Loop Volume

    Partial Injection = Set Volume < 1/2 of the sample Loop Volume

    Microliter Carry Injection =  set volume

    Minimum Injection Volume: 0.1 μL

    Sample Capacity: 2 × 54 1.5 mL injection bottles or 2 × 96 Well Plates

    Injection Reproducibility:

    Full Loop Injection: ≤0.3% RSD

    Partial Injection: ≤0.5% RSD (10 μL)

    Microliter Carry Injection: ≤1.0% RSD

    Cross Contamination: <0.005% (under specified conditions)

    Maximum Pressure Tolerance: 10500 psi

    Optional Cooling Function:4 ℃ - room temperature

    Column oven

    Temperature Control Method: Peltier Temperature Control

    Temperature Control Range: 10℃ to 80℃

    Column Capacity: 2 × 300mm Chromatography Columns or more shorter columns

    Detector

    Diode array detector

    Variable wavelength detector

    Wavelength range: 200nm-800nm

    Light source: deuterium lamp, tungsten lamp

    Spectral bandwidth: 10nm

    Wavelength range: 190-800nm

    Light source: deuterium lamp, tungsten lamp

    Spectral bandwidth: 6nm

    Wavelength accuracy: ± 1nm

    Wavelength repeatability: ± 0.5nm

    Flow cell volume: 16 uL, 10 mm optical path length

  • HPLC System-Hicient L-2000 Bio.pdf   

Contact Us

Products of Interest (Multiple Selection)
Services Needed (Multiple Selection)
Submit
%{tishi_zhanwei}%

Inscinstech Co., Ltd.

Provide integrated solutions for biopharmaceutical CMC from upstream and downstream processes to laboratory analysis.

Contact Us